INTRODUCTION

The Analox Hyper-Gas MkII TM is designed to detect and warn divers of, potentially fatal, anaesthetic levels of hydrocarbons in the diving bell. Where divers are working on dirty sites, there is a likelihood for contamination of the bell atmosphere from vapourisation of contaminants carried on dive suits and umbilical lines, even when divers are wearing additional safety dive suits. Vapourisation of hydrocarbons into the bell can occur within minutes and can rapidly rise to anaesthetic concentrations.

Real Dangers to Divers: in the presence of anaesthetic levels of volatiles divers can suffer the effects within a few breaths. Even before unconsciousness, the ability to react normally becomes impaired. The effects caused by sub anaesthetic levels can be compared with the pattern of behaviour caused by alcohol consumption. The following effects have been detailed by Fang et al. (1996):

  • 33% of the anaesthetic level of toluene leads to hyperactivity.
  • 13% of the anaesthetic level of xylene causes tremors which could impair purposeful actions.
  • 44% of the anaesthetic level of benzene causes uncontrolled jerking of limbs.
  • 52% of the anaesthetic level of cyclo-hexane causes convulsions.

How it Works: the Hyper-Gas MkII TM system comprises 2 units, both are equipped with audible and visual indicators to alert divers and surface engineers to changing conditions within the diving bell.

The bell monitor is mounted in the gas sample line, once installed the monitor will rapidly detect the presence of vapourised hydrocarbons, and will activate audible and visual alarms before the anaesthetic threshold is reached. Technology: the Analox Hyper-Gas MkII TM system has been designed to operate to depths up to 60 Bar A. It uses a unique hyperbaric hydrocarbon sensor based on highly respected Analox infra red technology. The sensor is sensitive to a range of hydrocarbons, and is able to detect all those commonly given off by the vaporisation of crude oil or condensate.

Automatic correction of pressure and temperature effects ensures the analyser will offer optimum performance in this difficult environment.

Gas Alarm: the Gas Alarm level is preset to 10% of the anaesthetic dose of vapourised hydrocarbons that could be present in the diving bell. The sensor gives an additive response to the range of hydrocarbons normally present, not one individual compound. For diving in areas where contamination is known to be from 1 or 2 compounds, the alarm set point can be altered.

Response Time: the sensor needs to be mounted within the diving bell, rather than relying on an umbilical fed analyser because anaesthesia, or the effects of sub anaesthetic levels can occur within a few breaths, i.e. a few seconds. By analysing for hydrocarbons at the surface it is likely that the effects would occur before an alarm is raised. A rapid response is crucial.

Next Steps

Choose an option below to find out more about Analox Hyper-gas Hydrocarbon Monitor MkII


  • Make Enquiry
    Detailed enquiry?
    Click here to submit your query and
    we'll respond within 48 hours.

  • Live Chat
    Have a quick question?
    Click here to start a live chat with
    one of the team.

  • Call us
    Prefer to speak direct?
    Click here for the contact details
    of your nearest office.

jfd-footerdivex-footer

In 2015 James Fisher Defence and Divex merged to form JFD.

Today, JFD serves customers in 81 countries across six continents.

Discover More

JFD Global logo HomeProductsCommercial ProductsGas ManagementAnalox AnalysersAnalox Hyper-gas Hydrocarbon Monitor MkII